E-mail:service@1001718.com
DR5200
DR5200 - 2-Wire / 10GHz Radar (FMCW) Level MeterThis device is a non-contact radar level meter that uses FMCW technology. It measures distance, level and volume of liquids and pastes.
DR5200的详细资料
DR5200
DR5200 - 2-Wire / 10GHz Radar (FMCW) Level Meter |
||
This device is a non-contact radar level meter that uses FMCW technology. It measures distance, level and volume of liquids and pastes. It is ideal for measuring the level of corrosive products with its PP or PTFE antenna options. Features
|
Specifications |
||
Measuring system |
|
Measuring principle |
2-wire loop-powered level transmitter; X-band (10 GHz) FMCW radar |
Application range |
Level measurement of liquids, pastes and slurries |
Primary measured value |
Distance and reflection |
Secondary measured value |
Level, volume, mass and flow rate |
Design |
|
Construction |
The measurement system consists of a measuring sensor (antenna) and a signal converter |
Options |
Integrated LCD display (-20..+60°C/ -4…+140°F); if the ambient temperature is not in these limits, the display switches off automatically |
High-temperature (HT) extension (if the process connection temperature is more than +150°C / +302°F - Metallic Horn antenna only) |
|
Straight antenna extensions |
|
"S" antenna extension |
|
"L" (right angle) antenna extension |
|
Antenna purging system |
|
Heating / cooling system (with or without the antenna purging system) |
|
Signal cable for remote housing version (refer to cable properties in "Electrical connection: Remote device version") |
|
Weather protection - for the compact version or the antenna housing (remote version). It cannot be ordered after delivery of the device. |
|
Max. Measuring range |
PTFE and PP Wave Horn antennas: |
DN80 / DN100 Metallic Horn antennas (installation only in stilling wells): |
|
DN150 / DN200 Metallic Horn antennas: |
|
Wave Guide antenna: |
|
Also depends on the dielectric constant of the product and the installation type. Refer also to "Antenna selection". |
|
Min. tank height |
1m/ 3.3 ft |
Top dead zone |
Minimum value: Antenna length + antennna extension length + 100 mm / 3.9¨ |
Beam angle (½ angle) of antenna |
PP Wave Horn: 10° |
PTFE Wave Horn: 10° |
|
Metallic Horn DN80 / 3¨: 16° - used only in stilling wells |
|
Metallic Horn DN100 / 4¨: 12° - used only in stilling wells |
|
Metallic Horn DN150 / 6¨: 8° |
|
Metallic Horn DN200 / 8¨: 6° |
|
Wave Guide / stilling well: n/a - the radar signal is inside the tube. |
|
Display and user interface |
|
Display |
LCD display |
Interface languages |
3 language pack options (the language is given in the customer order): |
Measuring accuracy |
|
Resolution |
1 mm/ 0.04¨ |
Repeatability |
±1 mm/ ±0.04¨ |
Accuracy |
Standard: ±10 mm / ±0.4¨, when distance < 10 m / 33 ft; ±0.1% of measured distance, when distance > 10 m / 33 ft |
Reference conditions acc. to EN 61298-1 |
|
Temperature |
+15...+25°C / +59...+77°F |
Pressure |
1013 mbara ±50 mbar / 14.69 psia ±0.73 psi |
Relative air humidity |
60% ±15% |
Target |
Metal plate in an anechoic chamber |
Operating conditions |
|
Temperature |
|
Ambient temperature |
-40…+80°C/ -40…+176°F |
Storage temperature |
-50…+85°C/ -58…+185°F |
PP Wave Horn antenna: |
|
PTFE Wave Horn antenna: |
|
Metallic Horn antenna / Wave Guide antenna: |
|
Pressure |
|
Process pressure |
PP Wave Horn antenna: |
PTFE Wave Horn antenna: |
|
Metallic Horn antenna / Wave Guide antenna: |
|
Purging system (option) |
Max. 6 barg / 87 psig (higher pressure on request) |
Heating / cooling system (option) |
Max. 6 barg / 87 psig (higher pressure on request) |
Other conditions |
|
Dielectric constant (?r) |
Direct mode: ≥1.8 |
Ingress protection |
IEC 60529: IP 66/67 |
NEMA 250: NEMA type 4X (housing) and type 6P (antenna) |
|
Maximum rate of change |
10 m/min / 32.8 ft/min |
Installation conditions |
|
Process connection size |
The nominal diameter (DN) should be equal to or larger than the antenna diameter. |
Process connection position |
Make sure that there are not any obstructions directly below the process connection for the device. For more data, refer to Installation on page 31. |
Dimensions and weights |
For dimensions and weights data, refer to Dimensions and weights on page 24. |
Materials |
|
Housing |
Standard: Polyester-coated aluminium |
Option: Stainless steel (1.4404 / 316L) |
|
Antenna options / Wetted materials |
PTFE Wave Horn antenna with a PTFE flange cladding |
PP Wave Horn antenna with a PP jacket/threaded process connection |
|
Stainless steel (1.4404 / 316L) Metallic Horn antenna with a PTFE process seal and an FKM/FPM, EPDM, Kalrez® 6375 or PFA O-ring gasket |
|
Stainless steel (1.4404 / 316L) Wave Guide antennas with a PTFE process seal and an FKM/FPM, EPDM, Kalrez® 6375 or PFA O-ring gasket |
|
Feedthrough |
PP Wave Horn antenna: this is a single-piece antenna (the feedthrough is filled with PP) |
PTFE Wave Horn antenna: this is a single-piece antenna (the feedthrough is filled with PTFE) |
|
Metallic Horn and Wave Guide antennas: Dual process seal system |
|
Cable gland |
Standard: none |
Options: Plastic (Non-Ex: black, Ex i-approved: blue); nickel-plated brass; stainless steel |
|
Weather protection (Option) |
Stainless steel (1.4404 / 316L) |
Process connections |
|
Thread |
PP Wave Horn antenna: G 1½; 1½ NPT |
Flange version |
|
EN |
PTFE Wave Horn antenna: DN50…150 in PN16, PN40 |
Metallic Horn and Wave Guide antennas: DN80…200 in PN16, PN40; others on request |
|
ASME |
PTFE Wave Horn antenna: 2¨…6¨ in 150 lb / 300 lb |
Metallic Horn and Wave Guide antennas: 3¨…8¨ in 150 lb / 300 lb; others on request |
|
JIS |
PTFE Wave Horn antenna: 50...150A in 10K |
Metallic Horn and Wave Guide antennas: 80…200A in 10K; others on request |
|
Other |
Others on request |
Electrical connections |
|
Power supply |
Terminals output - Non-Ex / Ex i: |
Terminals output - Ex d: |
|
Maximum current |
22 mA |
Current output load |
Non-Ex / Ex i: RL [Ω] ≤ ((Uext -12 V)/22 mA). For more data, refer to Minimum power supply voltage on page 17. |
Ex d: RL [Ω] ≤ ((Uext -16 V)/22 mA). For more data, refer to Minimum power supply voltage on page 17. |
|
Cable entry |
Standard: M20×1.5; Option: ½ NPT |
Cable gland |
Standard: none |
Options: M20×1.5 (cable diameter: 6...10 mm / 0.2...0.39¨); others are available on request |
|
Cable entry capacity (terminal) |
0.5…2.5 mm² |
Input and output |
|
Output signal |
4…20 mA HART® or 3.8…20.5 mA acc. to NAMUR NE 43 3 |
Resolution |
±3 µA |
Temperature drift |
Typically 50 ppm/K |
Digital temperature drift |
Max. ±15 mm / 0.6¨ for the full temperature range |
Error signal |
High: 22 mA; Low: 3.6 mA acc. to NAMUR NE 43 |
Approvals and certification |
|
CE |
This device fulfils the statutory requirements of the EC directives. The manufacturer certifies successful testing of the product by applying the CE mark. |
Vibration resistance |
EN 60068-2-64 |
Metallic Horn (without antenna extension options): 5 Hz to 100 Hz: 4g |
|
Metallic Horn, PTFE or PP Wave Horn: 3.5 mm up to 8 Hz and 10 m/s²: 1g, |
|
8.5 to 2000 Hz |
|
Explosion protection |
|
ATEX |
II 1/2 G, 2 G Ex ia IIC T6...T2 Ga/Gb or Ex ia IIC T6...T2 Gb; |
II 1/2 D, 2 D Ex ia IIIC T90°C Da/Db or Ex ia IIIC T90°C Db IP6X; |
|
II 1/2 G, 2 G Ex d ia IIC T6...T2 Ga/Gb or Ex d ia IIC T6...T2 Gb; |
|
II 1/2 D, 2 D Ex ia tb IIIC T90°C Da/Db or Ex ia tb IIIC T90°C Db IP6X |
|
IECEx |
Ex ia IIC T6…T2 Ga/Gb or Ex ia IIC T6…T2 Gb; |
Ex ia IIIC T90°C Da/Db or Ex ia IIIC T90°C Db IP6X; |
|
Ex d ia IIC T6...T2 or Ex d ia IIC T6...T2 Gb; |
|
Ex ia tb IIIC T90°C Da/Db or Ex ia tb IIIC T90°C IP6X |
|
cFMus - Dual Seal-approved |
NEC 500 |
XP-IS / Cl. I / Div. 1 / Gr. ABCD / T6; |
|
DIP / Cl. II/III / Div. 1 / Gr. EFG / T6; |
|
IS / Cl. I/II/III / Div. 1 / Gr. ABCDEFG / T6; |
|
NI / Cl. I / Div. 2 / Gr. ABCD / T6 |
|
NEC 505 |
|
Cl. I / Zone 0 / AEx d [ia] / IIC / T6; |
|
Cl. I / Zone 0 / AEx ia / IIC / T6; |
|
Cl. I / Zone 2 / AEx nA [ia] / IIC / T6; |
|
Hazardous (Classified) Locations, indoor/outdoor Type 4X and 6P, IP66, Dual Seal |
|
CEC Section 18 (Zone ratings) |
|
Cl. I, Zone 1, Ex d, IIC (Antenna: Zone 0), T6; |
|
Cl. I, Zone 0, Ex ia, IIC, T6; |
|
Cl. I, Zone 2, Ex nA, IIC, T6 DIP A21 IP66 TB 95°C |
|
CEC Section 18 and Annex J (Division ratings) |
|
Cl. I, Div. 1/2, Gr. ABCD; Cl. II, Gr. EFG; Cl. III, T6; |
|
NEPSI (pending) |
Ex ia IIC T2~T6 DIP A21 TA IP66; |
Ex d ia IIC T2~T6 DIP A21 TA IP66 |
|
INMETRO (pending) |
Ex ia IIC T6…T2 Ga/Gb |
Ex ia IIIC T90°C Da/Db IP6X |
|
Ex d [ia Da] IIC T6…T2 Ga/Gb |
|
Ex tb [ia Da] IIIC T90°C Db IP6X |
|
Other standards and approvals |
|
SIL |
Compact version only: SIL 2 - according to EN 61508 and for high/low demand mode operation |
EMC |
Electromagnetic Compatibility Directive 2004/108/EC in conjunction with EN 61326-1 (2006) |
Radio approvals |
R & TTE |
FCC Rules |
|
Industry Canada |
|
LVD |
Low-Voltage Directive 2006/95/EC in conjunction with EN 61010-1 (2001) |
NAMUR |
NAMUR NE 21 Electromagnetic Compatibility (EMC) of Industrial Process and Laboratory Control Equipment |
NAMUR NE 43 Standardization of the Signal Level for the Failure Information of Digital Transmitters |
|
NAMUR NE 53 Software and Hardware of Field Devices and Signal Processing Devices with Digital Electronics |
|
NAMUR NE 107 Self-Monitoring and Diagnosis of Field Devices |
|
CRN |
This certification is applicable for all Canadian provinces and territories. For more data, refer to the website. |
Construction code |
Metallic Horn and Wave Guide antennas: NACE MR0175 / ISO 15156; NACE MR0103 |
1 If the process connection temperature is more than 150°C/ 302°F and the device has Kalrez® 6375 or FKM/FPM gaskets, the device will also have an high temperature extension between the converter and the process connection. Kalrez® is a registered trademark of DuPont Performance Elastomers L.L.C.The process connection temperature must agree with the temperature limits of the gasket ma- terial. 2 Metaglas® is a registered trademark of Herberts Industrieglas, GMBH & Co., KG 3 HART® is a registered trademark of the HART Communication Foundation |
该产品由betway必威精简版 提供,销售商地址位于深圳市南山区前海路振业国际商务中心1206。请您仔细阅读产品使用说明书,正确使用。
如果想试用该产品,请本单位:
银飞电子主要销售通信设备、仪器仪表、电力设备、热工仪表、校准设备及工具配件。有多功能多产品校准器、电能功率校准器、活塞式压力计(气体、高压、液体、真空)、多功能电气安全校准器、示波器、频率计、万用表、阻抗分析仪、功率计、LCR数字电桥、音频分析仪、电容测试仪、电感测试仪、安规测试仪、直流电阻测试仪、网络分析仪、频谱仪、任意波形发生器、温度校准仪、数字测温仪、信号发生器、电源、电子负载、综合测试仪、信号源、滤波器测试仪、材料试验机、温度传感器、热像仪、变压器测试仪、噪声源、视频分析仪、过程校准仪、温度巡检仪、超级测温电桥、黑体炉、射频导纳物位开关、多点物位开关、音叉开关、射频导纳连续物位计、雷达液位计、超声波液位计、油中水含量分析仪、液位测量系统、磁致伸缩液位计、非接触固体雷达、压力传感器、过程表、压力变送器、气动控制器、高纯压力开关、隔膜片、冲液表、计量表膜片密封、必威官方登录网页 、食品质构仪、硬度实验机、数字测力计、PETPLUS特性粘度仪、布氏光学扫描系统、洛氏布硬度实验机、全自动显微硬度试验机、布氏硬度试验机、电动试验平台、单柱材料试验系统、双柱材料试验系统、浮球活塞压力计、船用温度压力校验仪、点位测量系统、超声波开关、油/水界面开关、在线流体检测开关、多点开关、平板开关、浮顶罐溢出保护开关、空气加热器、织物加热套、电加热带、硅橡胶加热毯、圆桶加热器、IBC加热器、气体加热器、灰斗加热系统、自限温电伴热带、恒功率电伴热带、恒功率电伴热带、覆套式电阻加热器、电阻丝、温度控制器、危险环境加热器及控制、复合材料修补仪、真空修补/处理平台、A320升降舵无损检验包;静电放电干扰模拟器、雷击浪涌干扰模拟器、周波跌落模拟器、辐射抗扰度系统、脉冲群干扰模拟器、传导抗扰度测试系统、传导干扰测试系统、辐射干扰测试系统等仪器。
欢迎关注我们网站平台
|
||||